Trailer Mounted Air Cooled Chiller
Agency: | |
---|---|
Level of Government: | Federal |
Category: |
|
Opps ID: | NBD00159192057482069 |
Posted Date: | Nov 9, 2023 |
Due Date: | Nov 13, 2023 |
Source: | https://sam.gov/opp/c93c821690... |
APEX Accelerators are an official government contracting resource for small businesses. Find your local APEX Accelerator (opens in new window) for free government expertise related to contract opportunities.
APEX Accelerators are funded in part through a cooperative agreement with the Department of Defense.
The APEX Accelerators program was formerly known as the Procurement Technical Assistance Program (opens in new window) (PTAP).
- Contract Opportunity Type: Combined Synopsis/Solicitation (Updated)
- All Dates/Times are: (UTC-06:00) CENTRAL STANDARD TIME, CHICAGO, USA
- Updated Published Date: Nov 09, 2023 01:33 pm CST
- Original Published Date: Nov 02, 2023 10:48 am CDT
- Updated Date Offers Due: Nov 13, 2023 12:00 pm CST
- Original Date Offers Due: Nov 09, 2023 04:00 pm CST
- Inactive Policy: 15 days after date offers due
- Updated Inactive Date: Nov 28, 2023
- Original Inactive Date: Nov 24, 2023
-
Initiative:
- None
- Original Set Aside: Total Small Business Set-Aside (FAR 19.5)
- Product Service Code: 4130 - REFRIGERATION AND AIR CONDITIONING COMPONENTS
-
NAICS Code:
- 333415 - Air-Conditioning and Warm Air Heating Equipment and Commercial and Industrial Refrigeration Equipment Manufacturing
-
Place of Performance:
Dyess AFB , TX 79607USA
The 7th Civil Engineering Squadron on Dyess AFB requires a trailer mounted air-cooled chiller. The specifications are listed below:
1. One (1) new trailer mounted air-cooled chiller, chilled water pump, chilled water hoses and electrical cable ready to support multiple locations.
2. One (1) new bumper pull trailer rated for the equipment being provided. All new equipment to be mounted on the trailer.
3. One (1) new Dunham-Bush air-cooled chiller as follows:
a. Air-Cooled Scroll Packaged Chiller
b. 20 Nominal Tons
c. Scroll Compressors
d. 460 volt 60 hertz 3 phases – Single point connections
e. Unit mounted main disconnect switch
f. Full factory refrigerant charge (HFC-134a)
g. With freeze protection (requires separate 115v power)
h. Low ambient control to 0F
i. Shell & Tube Heat Exchanger
j. Micro-channel Condenser
k. 115F maximum ambient temperature
l. Refrigerant isolation valves (discharge valve)
m. Louvered Hail Guard
n. Field installed flow switch
o. Victaulic connection
p. Factory insulation
q. Rubber and shear vibration isolation
r. Factory mounted controller w/ BACnet/IP
s. 5 year compressor parts warranty
4. One (1) new chilled water pump rated for the new chiller. Pump to be mounted on the trailer and hard piped to the new chiller. Pump will be provided with cam-lock style fittings for future hose connections.
5. Four (4) ea., fifty (50) foot sections of 4” flexible hose with associated camlok fittings.
6. Four (4) ea., one hundred (100) foot sections of 500 MC cable with male/female connections.
7. Trailer to be mounted with a single point new 480/3/60 panel that will serve the new chiller & chilled water pump. The trailer mounted chiller will control the new chilled water pump.
Please reach out to A1C Alan M. Mwamba at (325)696-1458 or alan.mwamba.ke@us.af.mil if you have any questions.
- CP 325 696 2285 381 3RD ST
- DYESS AFB , TX 79607-1581
- USA
- Alan Mwamba
- alan.mwamba.ke@us.af.mil
- Phone Number 3256962215
- Jerime W. Gorse
- jerime.gorse@us.af.mil
- Phone Number 3256965569
- Nov 09, 2023 01:33 pm CSTCombined Synopsis/Solicitation (Updated)
- Nov 09, 2023 08:54 am CST Combined Synopsis/Solicitation (Updated)
- Nov 08, 2023 03:05 pm CST Combined Synopsis/Solicitation (Updated)
- Nov 08, 2023 10:55 am CST Combined Synopsis/Solicitation (Updated)
- Nov 02, 2023 10:48 am CDT Combined Synopsis/Solicitation (Original)
TRY FOR FREE
Not a USAOPPS Member Yet?
Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.