Texas Bids > Bid Detail

6640--629-23-2-340-0030 Microtome VT (VA-23-00041772)

Agency: VETERANS AFFAIRS, DEPARTMENT OF
Level of Government: Federal
Category:
  • 66 - Instruments and Laboratory Equipment
Opps ID: NBD00159592718705833
Posted Date: Feb 16, 2023
Due Date: Feb 17, 2023
Solicitation No: 36C25623Q0456
Source: https://sam.gov/opp/3faa80a8be...
Follow
6640--629-23-2-340-0030 Microtome VT (VA-23-00041772)
Active
Contract Opportunity
Notice ID
36C25623Q0456
Related Notice
Department/Ind. Agency
VETERANS AFFAIRS, DEPARTMENT OF
Sub-tier
VETERANS AFFAIRS, DEPARTMENT OF
Office
256-NETWORK CONTRACT OFFICE 16 (36C256)
Looking for contract opportunity help?

Procurement Technical Assistance Centers (PTACs) are an official government contracting resource for small businesses. Find your local PTAC (opens in new window) for free government expertise related to contract opportunities.

General Information
  • Contract Opportunity Type: Presolicitation (Original)
  • All Dates/Times are: (UTC-06:00) CENTRAL STANDARD TIME, CHICAGO, USA
  • Original Published Date: Feb 16, 2023 03:19 pm CST
  • Original Response Date: Feb 17, 2023 11:00 am CST
  • Inactive Policy: Manual
  • Original Inactive Date: Mar 04, 2023
  • Initiative:
    • None
Classification
  • Original Set Aside: Service-Disabled Veteran-Owned Small Business (SDVOSB) Set-Aside (FAR 19.14)
  • Product Service Code: 6640 - LABORATORY EQUIPMENT AND SUPPLIES
  • NAICS Code:
    • 339113 - Surgical Appliance and Supplies Manufacturing
  • Place of Performance:
    Michael E. DeBakey VA Medical Center 2002 HOLCOMBE BLVD HOUSTON , TX 77030
    USA
Description
Suggested Manufacturer Brand Name: Leica VT1200 Semiautomatic Vibrating Blade
Microtome OR EQUIVALENT as listed below:
Specifications/Salient Characteristics:I made formatting changes here that I did not track. Please review to ensure I have not inadvertently changed the meaning.

Some of these items are not salient characteristics, they appear to be a reproduction of Leica promotional material.
Instrument features:
Includes blade holder, ice tray, buffer tray metal,and specimen disc
Semiautomatic Vibrating Blade Microtome for sectioning fixed and unfixed specimens from Neuropathology, Neurophysiology (Patch clamping), Botany (FboNotices and parts of plants) and Industry (foams).
Robust and stabile basic instrument with blade holder for safe insertion of the whole razor blade and adjustment screw screwFor example, are these adjustments made in other devices by means other than an adjustment screw?
You deleted the reference to a screw in another location so I propose deleting this one as well.
to minimize the vertical deflection of the blade below 1 µm.
Separate control panel foil protected. Adjustment for manual feeding prior to each section (semiautomatic cutting mode).

Support for removable ice tray, double walled buffer tray or optional measurement device, Is Vibrocheck specific to the Leica machine?
for vertical deflection of the blade below 1 um.

Technical specifications:

Vertical specimen feed: max. 20 mm (depending on selected specimen holder)

Horizontal stroke: 45 mm

Blade holder turntable must be safe for blade removal and insertion of whole razorinjector or sapphire blades.

Optimized blade holder design for minimized buffer spillage.

Separate control panel foil protected

Protected Parameter setting for speed, amplitude, section thickness (semiautomatic mode)

Display for vertical blade deflection value (in µm) and indication of screw turn direction to minimize the vertical blade deflection when using measurement device "Vibrocheck"

Motorized blade holder vibration with minimal vertical blade deflection (value measurable by optional measurement devi. Value can be minimised by using adjustment screw on blade holder).

Motorised blade holder travel speed adjustable between 0.01 1.5 mm/s in:
0.1
in 0.01 mm/s steps
0.5
in 0.02 mm/s steps
0.5 1.5
in 0.1 mm/s steps
Accelerated motorised blade return travel speed of 2.5 mm/s

Manual blade forward and return speed of 1.5 mm/s
Amplitude adjustment: 03 mm in 0.05 mm steps
Frequency: 85 Hz +/5 Hz
"Up" button for fast approach of the specimen to the blade
"Down" button for fast approach of the home position for safe and fast specimen change
Adjustment screw for manual feeding prior to each section
Adjustable step sizes for manual feeding: 1, 10 or 100 µm
Memo button to save selected section thickness
Section thickness totalizer, resettable at any position
Integrated LED illumination
Adapter for magnifier or microscope carrier
Removable ice tray, drawer principle, allows preparation of the tissue under the microscope with integrated palm rests with magnets to hold buffer tray in place
Buffer tray (plastics) with lid to cover up buffer tray while filling ice tray, magnet to hold specimen disc in place, specimen disc nonorienting and clamp to hold tube in buffer during oxygenation. Volume: 125 ml, autoclavable
Attachments/Links
Contact Information
Contracting Office Address
  • 715 SOUTH PEAR ORCHARD RD., PLAZA 1
  • RIDGELAND , MS 39157
  • USA
Primary Point of Contact
Secondary Point of Contact


History
  • Feb 16, 2023 03:19 pm CSTPresolicitation (Original)

TRY FOR FREE

Not a USAOPPS Member Yet?

Get unlimited access to thousands of active local, state and federal government bids and awards in All 50 States.

Start Free Trial Today >